ARC6 6.6.247.15 TRIAL RELEASE - KIT REVISION 1
WINDOWS X64 DESKTOP RELEASE CANDIDATE
EXISTING-INSTANCE UPGRADE GUIDE (x64)
Includes native SQLite clean databases and SQL CE transition conversion. Isolated legacy/current upgrade and rollback checks pass; target-host and manual acceptance remain pending.

WHAT TO RUN

Extract the complete ZIP into a short writable folder outside the
installation. Keep its files together and run ARC6-Setup.exe. This upgrades an
existing ARC6 instance. Clean Setup source is included for separate acceptance; use a new or empty directory only when deliberately testing a clean installation. Read
release-notes.txt for changes since the last published release. This is a
Trial upgrade kit. Login, concurrent-session, reconnect escalation,
persistent-client quarantine and manual IP blocking default to Enforce. One
pre-.141 migration promotes quarantine/manual-IP Observe modes to Enforce and
optional spot-permission Observe to Off. Explicit Off/Enforce choices, lists
and numeric limits remain; later sysop choices persist. Leave recommended
settings alone unless monitoring shows a legitimate-traffic problem. Imported
inbound blocks retain their policy. See documentation/pc9x-peer-testing.txt
for the limited-node protection checklist. See
documentation/saved-dx-filters.txt for the new named-filter commands,
read-only callsign sharing, examples and manual acceptance checklist.

UPGRADE

1. Record the callsign/SSID, current version and exact installation directory.
   Keep your backup and maintenance folders. On a multi-instance host,
   identify the intended instance carefully.
2. Run ARC6-Setup.exe and select the directory containing that ArcServer.exe.
   Verify the selected callsign/path. Stop that instance normally or use
   Setup's stop option; close its open dialogs if it cannot stop. Keep it
   stopped during the upgrade. Other instances can remain running.
3. Wait for the final result. Database validation may take several minutes.
   Setup checks .NET Framework 4.8 and Windows PowerShell 5.1 prerequisites.
   The guided x64 Setup requires Windows 8.1 / Server 2012 R2 or newer.
4. On success, record the resulting installation path and review the log. A
   legacy installation under Program Files (x86) may relocate to Program
   Files; matching shortcuts are retargeted. Custom paths upgrade in place.
   Services or scheduled tasks pointing to an old path need separate handling.
5. Start manually, or select Setup's optional start checkbox when ready.
   Confirm the version shown at the top of this guide, callsign/SSID,
   listeners, peers, feeds, profiles, filters and history. Review the focused
   checks below before updating others.

LIMITED-NODE UPGRADE AND SOAK CHECKS

Upgrade one selected node first. After it passes startup and traffic checks,
expand only at the operator's chosen pace. A successful limited-node soak does
not by itself qualify every installation or a public release.

1. Record the node's current version and installation path. Run the extracted
   ARC6-Setup.exe on NT7G-SERVER, select that exact instance, and verify its
   callsign/path before upgrading. Close open dialogs and stop normally.
2. Let conversion and recovery-archive verification finish. Check the final
   success result and resulting path before starting the server.
3. Confirm the version shown at the top of this guide, the correct callsign/SSID,
   existing listeners, peers and RBN feeds. Connect as a normal user; check real
   spots and normal commands.
4. Check retained history, user profiles and named filters. Verify Security
   Monitor and your usual filters; make a small reversible setting change,
   restart normally, and confirm it persists and traffic resumes.
5. If deliberately testing rollback on a quiet trial node, stop normally and
   open the extracted kit's
   Support/ARC6-Maintenance.exe with --advanced ONLY (no path argument).
   Select the installation path, choose its most recent pre-upgrade version
   checkpoint, then check that it is stopped and click Roll back. The original
   baseline may be much older.
   A path argument currently opens interruption recovery only. Windows
   Installed Apps offers Update/Repair, not a direct normal rollback button.
   Confirm the restored version starts. Rollback restores checkpoint data;
   newer history/settings are not carried back. Keep all recovery archives
   and re-run the full transition ARC6-Setup.exe to return to SQLite.
6. Use a disposable test instance for clean-install/uninstall/reinstall
   acceptance; do not use active soak nodes for destructive clean tests.

Report the selected node, prior/resulting version, final Setup result and any
unexpected behavior. Preserve the upgrade log on failure and do not delete
maintenance/recovery folders. UI acceptance is operator-owned.

REVIEW THIS UPDATE

- Review Setup labels, summaries and lower help. RBN row selection should only
  select; its ellipsis or RBN Feeds button opens the editor. Legacy publishing
  settings are hidden.
- Check Continent, Country Prefix and State / Province. US/Canadian lookup
  data should resolve; missing lookup data is blank; other countries show N/A.
- Standard HamQTH HTTP XML URLs migrate to HTTPS; custom endpoints are
  preserved. Check upgrade history. Application logs roll daily and at 100 MB;
  protocol logs remain at 10 MB. Existing positive WCY result limits remain
  unchanged; the new default is 24.
- Press empty Enter and run commands using CR-only input. Verify one final
  prompt with full login callsign/SSID and UTC time after each command.
- For FT Mode TXOffset choose RBN port 7002 explicitly. Existing port 7001 is
  preserved. RBN/skimmer spots must remain local-only, never sent to peers.
- Check Tools > User Session History, welcome {LATESTWCY}, node callsign
  changes and normal PC11/PC61 peer traffic as relevant to your installation.

RECOVERY AND SUPPORT

Keep the operation log and generated logs-only support ZIP. On failure keep
ARC6 stopped and review the result before retrying. Setup identifies an
interrupted operation after you select its original instance path, and offers
Recover interrupted operation. The recovery window is locked to that instance.
Ordinary upgrades do not show a maintenance choice. Checkpoint rollback and
ProgramData moves remain explicit engineering actions until the full
maintenance lifecycle is implemented; they are not repair. Working
helpers/scripts are in Support. Top-level compatibility EXEs open Setup only;
keep them for older Check for Updates clients. Do not run files in Support
manually. Setup retains the original backup by default. Subsequent operations
keep the three most recent complete checkpoints. In Maintenance select a
checkpoint by version and date; the most recent is selected by default. The
original backup remains an explicit choice until you delete it. Use Delete
Selected Checkpoint to remove the original backup only if a newer complete
checkpoint can be verified. Setup preserves that newest checkpoint. Each rollback restores its
binaries, databases and configuration together, including active ProgramData
for bound installations. Later user/configuration/history changes are not
merged. The current installation is saved before rollback so it can also be
restored. Only verified obsolete checkpoints are pruned, after success.
Damaged backups stop restoration. Never start a retained checkpoint directly
or delete maintenance folders casually. Operator checks: perform consecutive
upgrades on a limited node, verify the original plus at most three recent
entries, then restore a recent checkpoint and confirm its version,
users/settings and matching database. Verify the saved pre-rollback point can
restore the newer version. Check ProgramData if in use.

PACKAGE CONTENTS

Scripts, validation source under Support/tests, manifests and runtime
libraries are required by the updater. They are not optional development
extras. Third-party license notices must remain. No private databases,
licenses, profiles or credentials are included. UI, upgrade and live-node
acceptance are performed by the operator.

AUTOMATIC RESTART: Setup preserves the running instance's verified Windows
account and privilege level. If already stopped before inspection or
credentials cannot be safely matched, Setup leaves ARC6 stopped and directs
you to the usual shortcut. Actual administrator and normal-user Setup
final-checkbox tests remain operator-owned.

FAILURE HANDLING

Operation logs remain in <installation>.ARC6-maintenance/SetupLogs after
closing Setup. Only restart after failure if Setup explicitly verifies the
original program and data unchanged; otherwise follow its recovery guidance.
The package uses precompiled migration, lease and binding support and has no
destination-compiler fallback for normal upgrades. Keep original backups and
recovery evidence. No diagnostic upload command, prompt or reporting transport
is delivered.